Compromise matrix construction details

December 11, 2015 JimK 4 Comments

This is the fifth in a series of posts on color reproduction. The series starts here.

This is a nerdy and mathematical, though equation-free, take on how to create compromise matrices. If you don’t know what a compromise matrix is, start with the link in the paragraph above. If you just want a semi-technical view from 30,000 feet, look here.

In a perfect world, here’s how I would build a compromise matrix for a non-Luther digital camera.

I’d take a reflectance spectrophotometer – an instrument that I have never seen — and measure the reflectance vs wavelength for all the subjects of interest to me. I could also take a plain old spectrophotometer, set it to a broad illuminant with no peaks like D50, measure all the subjects, and divide the measurements wavelength by wavelength by the spectrum of the illuminant.

Then I’d measure the spectrum of all the illuminants that are important to me.

I’d do a wavelength by wavelength multiply of the reflectance spectra of the n subjects by the spectra of the m illuminants to get m*n spectra that I care about that will be imaged by the camera.

I’d fire up a special printer that can print samples with arbitrary spectral reflectance (a printer which I’m pretty sure doesn’t exist), and print little squares with each of the m*n spectra on a target substrate.

I’d evenly illuminate the target with a light source that has equal energy at each wavelength from 380 through 720 nm. Or, I could illuminate the target with some non-peaky source like D50 and compensate for its lack of spectral whiteness when I printed the target.

I’d photograph the target with the camera for which I wished to compute the compromise matrix.

I’d take the spectra of the samples and convert them each to Lab. I’d arrange the Lab values of each sample as a column vector, and construct a 3 by n*m matrix by concatenating all the samples in the horizontal direction.

I’d take each color plane of the mosaiced raw image, average the values in the vicinity of each sample, and further average the two green planes, giving me R, G, and B samples for each of the m*n squares. I’d arrange the RGB values of each sample as a column vector, and construct a 3 by n*m matrix by concatenating all the samples in the horizontal direction.

I’d probably use the camera manufacturer’s suggested white balance setting for each illuminant, normalize to G = 1 if necessary, and perform the corrections, giving me a 3 by n*m matrix of white balanced raw values. I’m not a fan of doing white balance correction in raw, but it seems to be a kind of standard way of doing things.

I’d start out with the test compromise matrix as the camera manufacturers recommended matrix in the EXIF metadata or in dcraw. Let’s assume the matrix is supplied as CIE 1931 XYZ to camera “color”, as it usually is. I put the “color” part of “camera color” in quotes because we have already said this is not a Luther camera, so it doesn’t see color the way that humans do. I’d invert that matrix to get from camera “color” to XYZ, and that would be my initial guess at a compromise matrix.

I’d multiply each column in the white balance corrected sample matrix by the compromise matrix to get to XYZ. Then I’d convert to CIELab, using the XYZ values of one of the neutral squares under D50 illuminant as a white reference.

I’m not sure what I’d do about the possible (probable?) occurrence of a situation where the D50 neutral squares a* and b* values turned out to be nonzero. A separate white balance step, XYZ to XYZ, before conversion to Lab? Do it for each illuminant?

In any event, now we have two 3 by n*m matrices in Lab. If absolute color error is the long pole in the tent, we subtract them to form an error matrix, then apply some function that weights it and yields all positive terms, then sum it to get a scalar error. But in general, luminance errors are more readily tolerated in photography than hue angle errors, and chroma errors may actually be desirable if they are the result of slightly more chromatic captures. So I might convert the Lab matrices to LCH, subtract them, weight them to taste, then sum get my scalar error function.

Then I’d put all of the last three paragraphs inside an optimum seeking method that’s tolerant of local minima, and let it run overnight, yielding an optimum compromise matrix.

A lot of the above is practical. What is not is creating a target that has the spectral responses of all subjects of interest under all illuminants of interest. Without that target, getting a compromise matrix that works well with many subjects is problematic.

What’s to be done?

  • Compute compromise matrices for each illuminant, thereby simplifying the problem.
  • Use a commercial target that has spectral reflectances that are deemed to be useful by many photographers. The hoary old Macbeth chart is one such target, but has the disadvantage that the number of patches is quite small.
  • Print out targets with an inkjet printer. This is looking for your keys under the streetlight, but is extremely risky. Who says that the spectral reflectances of real world subjects are at all related to those of printer inksets?
  • Find something that’s kinda, sorta close, and fix the colors to taste in post.

My guess is that most people do the last one.

By the way, in my research into this matter, I’ve found some useful references.

Here’s a primer on raw processing and color conversion. It’s written for Matlab users, but should be useful to others.

Here’s a step-by-step walkthrough of creating compromise matrices (not 3×3, but 4×3). There are several things that I disagree with here, but it’s still worth a look. A set of useful Matlab routines are in the appendix.

Here’s how the Imatest color correction module works.

Note that much the same processing that gets a compromise matrix for raw to some working space could also be used to go from one working space to another. The noise might be a bit worse in some places, but you could develop compromise matrices to be used pretty much anywhere in Lightroom or Photoshop.

The Last Word

← Constructing a compromise matrix Finding compromise matrices through simulation →

Comments

  1. Lynn Allan says

    December 12, 2015 at 5:14 pm

    Rather esoteric.

    IIRC, about a year ago, Ben Goren on the colorsync forum described calibration involving 1000+ patches, including a “black trap” and a nearly white teflon’ish material. I don’t know what came of that.

    Reply
  2. Al Sawyer says

    June 23, 2020 at 3:42 am

    This is a fascinating series. I am not afraid of the math, but the color vocabulary is outside my experience.

    The correct URL is now https://rcsumner.net/raw_guide/RAWguide.pdf

    Reply
    • JimK says

      June 23, 2020 at 6:46 am

      Thanks. Fixed now.

      Reply

Trackbacks

  1. Finding compromise matrices through simulation | The Last Word says:
    December 13, 2015 at 8:36 am

    […] my last post, I suggested a “perfect world” approach to generating compromise matrices. This approach […]

    Reply

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

May 2025
S M T W T F S
 123
45678910
11121314151617
18192021222324
25262728293031
« Apr    

Articles

  • About
    • Patents and papers about color
    • Who am I?
  • How to…
    • Backing up photographic images
    • How to change email providers
    • How to shoot slanted edge images for me
  • Lens screening testing
    • Equipment and Software
    • Examples
      • Bad and OK 200-600 at 600
      • Excellent 180-400 zoom
      • Fair 14-30mm zoom
      • Good 100-200 mm MF zoom
      • Good 100-400 zoom
      • Good 100mm lens on P1 P45+
      • Good 120mm MF lens
      • Good 18mm FF lens
      • Good 24-105 mm FF lens
      • Good 24-70 FF zoom
      • Good 35 mm FF lens
      • Good 35-70 MF lens
      • Good 60 mm lens on IQ3-100
      • Good 63 mm MF lens
      • Good 65 mm FF lens
      • Good 85 mm FF lens
      • Good and bad 25mm FF lenses
      • Good zoom at 24 mm
      • Marginal 18mm lens
      • Marginal 35mm FF lens
      • Mildly problematic 55 mm FF lens
      • OK 16-35mm zoom
      • OK 60mm lens on P1 P45+
      • OK Sony 600mm f/4
      • Pretty good 16-35 FF zoom
      • Pretty good 90mm FF lens
      • Problematic 400 mm FF lens
      • Tilted 20 mm f/1.8 FF lens
      • Tilted 30 mm MF lens
      • Tilted 50 mm FF lens
      • Two 15mm FF lenses
    • Found a problem – now what?
    • Goals for this test
    • Minimum target distances
      • MFT
      • APS-C
      • Full frame
      • Small medium format
    • Printable Siemens Star targets
    • Target size on sensor
      • MFT
      • APS-C
      • Full frame
      • Small medium format
    • Test instructions — postproduction
    • Test instructions — reading the images
    • Test instructions – capture
    • Theory of the test
    • What’s wrong with conventional lens screening?
  • Previsualization heresy
  • Privacy Policy
  • Recommended photographic web sites
  • Using in-camera histograms for ETTR
    • Acknowledgments
    • Why ETTR?
    • Normal in-camera histograms
    • Image processing for in-camera histograms
    • Making the in-camera histogram closely represent the raw histogram
    • Shortcuts to UniWB
    • Preparing for monitor-based UniWB
    • A one-step UniWB procedure
    • The math behind the one-step method
    • Iteration using Newton’s Method

Category List

Recent Comments

  • JimK on Goldilocks and the three flashes
  • DC Wedding Photographer on Goldilocks and the three flashes
  • Wedding Photographer in DC on The 16-Bit Fallacy: Why More Isn’t Always Better in Medium Format Cameras
  • JimK on Fujifilm GFX 100S II precision
  • Renjie Zhu on Fujifilm GFX 100S II precision
  • JimK on Fuji 20-35/4 landscape field curvature at 23mm vs 23/4 GF
  • Ivo de Man on Fuji 20-35/4 landscape field curvature at 23mm vs 23/4 GF
  • JimK on Fuji 20-35/4 landscape field curvature at 23mm vs 23/4 GF
  • JimK on Fuji 20-35/4 landscape field curvature at 23mm vs 23/4 GF
  • Ivo de Man on Fuji 20-35/4 landscape field curvature at 23mm vs 23/4 GF

Archives

Copyright © 2025 · Daily Dish Pro On Genesis Framework · WordPress · Log in

Unless otherwise noted, all images copyright Jim Kasson.